IG Electrocardiograph EKGseries12CH
Electrocardiographs
Our 12-Channel EKG from our EKG Series comes with a smart and portable design offering an extremely simple and adaptable touch-screen interface. Patient information along with vital sign settings can be quickly modified to meet the needs of a patient´s changing condition. Users have access to a quick and convenient analysis while having multiple prints and data transfer options. The diagnostics applications check cardiac abnormalities, detect chest pain with acute myocardial ischemia and myocardial infarction, and also evaluate the patients arrhythmias.
IG Medical 12-Channel EKG Suitable for adults, pediatrics, and neonates.
- Analysis for children and newborn
- 250Hz low-pass, an exclusive module for children and newborns
- Auto-trigger mode
- The auto-recording function triggers as soon as the arrhythmia is detected
- 30-300 sec. of R-R analysis and arrhythmia detection
- Up to 200 kinds of arrhythmia Analyses
- Auto printing function
- Waveform freezing
- Latest 300 seconds waveforms are reviewable and recordable
1
- 9" LCD Touch Screen -
- Very high sensitivity and specificity of QRS detection with handwriting support
- 1:1 ratio waveforms
- Four sensitivity levels with grid line background
- 3 operation keys
- Data format: pdf, jpeg, dicom, xml for efficiency improvement
- Unique ECG data acquisition module - Easy data search
- Independent lead wires
- Waterproof alphanumeric keys
- USB / SD card / internal storage
- HL7 support, LAN, VGA and WIFi-option
- Auto- and manual recording
- Long term recording up to 300 sec
- Onscreen operation guide
- Rechargeable battery for up to 3h working time
- Analysis interpretation by Minnesota code with CSE & AHA database support
2
Display | 9“ LCD touch screen |
---|---|
Lead | Standard 12-leads simultaneous acquisition |
Patient cable | Standard cable with ECG defibrillation-proof |
Long term recording | Record for a long term (30sec ~ 300sec) and rhythm analysis |
Measurement parameters | Ventricular rate, PR interval, QRS time limit, QT/QTC interval, P/QRS/T axis, RV5/SV1 amplitude and RV5+SV1 amplitude |
Filters | AC, drift and myoelectric filters |
CMRR | > 60dB, >100 dB (with AC interference filter) |
Input impedance | > 50m Ω |
Frequency response | 0.05 ~ 250Hz |
Patient leakage current | < 10μa |
Input circuit current | ≤ 0.1μa |
Time constant | ≥ 3.2s |
Sensitivity | 2.5, 5, 10/5, 20/10mm/mv, auto gain |
Paper speed | 5, 6.25, 10, 12.5, 25, 50mm/s |
Recording paper | 210mm x 150mm x 200mm p fan-fold paper (A4 width) |
Operation mode | Auto., manual, rhythm, cabrera, paper save, cycle print |
Calibration rates | 1mV, zeroing reset, auto-base line correction |
DC | 14.8V rechargeable li-ion battery, 3h working time |
Power supply AC | 100-240V, 50/60Hz, 110 VA |
Safety level | IEC class II, type CF |
Environment requirements | Temp.: +5°C ~ +40°C Relative humidity: ≤ 95% (no condensation) Air pressure: 86KPa ~ 106 KPa |
Supporting various data memory | Internalmemoryupto3000files,SDcardformassivedata storage, External USB flash drive for easy data transmission |